Simultaneous analysis of particle size and electrostatic charge distribution using Phase Doppler Anemometry

J Kulon*, B Malyan

*Corresponding author for this work

    Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

    Abstract

    The proposed, non-invasive method of measurement of the charge level on a population of particles employs the Phase Doppler Anemometry (PDA) technique in conjunction with a high-resolution computer controlled traversing system. The PDA system was used to track the motion of charged particles in the presence of a DC electric field. By solving the equation of a particle motion in a viscous medium combined with the simultaneous measurement of its size and velocity the magnitude as well as the polarity of the particle charge can be resolved. In order to detect particles with high electrical mobility and to cover the wide range of electrostatic charges the probe volume was moved mapping the velocity of the particles within the space between the parallel plate electrodes. The preliminary experimental tests were carried out on dioctyl phthalate aerosol droplets produced by nebulising isopropanolic solutions using a Medic-Aid Sidestream nebuliser. The experimental results show that inherent electrostatic charge on dioctyl-phthalate droplets ranged from -250 to 250 electrons with an average charge-to-mass ratio of 0.24muC/g. In case of precharged aerosol the average charge-to-mass ratio increased to 20muC/g. The results presented demonstrate capability of the technique to allow real-time determination of particle size and charge with a high particle count rate in order of several thousands particles per second.

    Original languageEnglish
    Title of host publicationConference Record of the 2002 IEEE Industry Applications Conference
    Subtitle of host publication37th IAS Annual Meeting
    PublisherInstitute of Electrical and Electronics Engineers
    Pages984-989
    Number of pages6
    ISBN (Print)0-7803-7420-7
    DOIs
    Publication statusPublished - 2002
    Event37th Annual Meeting of the Industry-Applications-Society - PITTSBURGH, United Kingdom
    Duration: 12 Oct 200218 Oct 2002

    Publication series

    NameIEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING
    PublisherIEEE
    ISSN (Print)0197-2618

    Conference

    Conference37th Annual Meeting of the Industry-Applications-Society
    Country/TerritoryUnited Kingdom
    CityPITTSBURGH
    Period12/10/0218/10/02

    Keywords

    • phase Doppler
    • electrostatic charge measurement
    • ELECTRIC CHARGE
    • DEPOSITION
    • LUNG

    Fingerprint

    Dive into the research topics of 'Simultaneous analysis of particle size and electrostatic charge distribution using Phase Doppler Anemometry'. Together they form a unique fingerprint.

    Cite this