Crynodeb
ObjectiveTo determine interrater agreement and test-retest reliability of the parallel walk test (PWT), a simple method of measuring dynamic balance in the elderly during gait. DesignCohort study. SettingOutpatient clinic. ParticipantsElderly fallers (N=34; mean ± SD age, 81.3±5.4y) registered at a falls clinic participated in this study based on Mini-Mental State Examination and Barthel Index scores. InterventionsSubjects were timed as they walked 6m between 2 parallel lines on the floor at 3 different widths (20, 30.5, 38cm) wearing their own footwear. They were scored for foot placement on (1 point) or outside the lines (2 points) by 2 separate raters. Fifteen subjects were retested 1 week later. Main Outcome MeasuresFootfall score and time to complete the PWT. Intraclass correlation coefficients (ICCs) and 95% limits of agreement were calculated for interrater and test-retest reliability. ResultsFor widths of 20, 30.5, and 38cm, interrater reliability ICC range was .93 to .99 and test-retest ICC range was .63 to .90. ConclusionsThe PWT was implemented easily by 2 raters with a high degree of interrater reliability. Test-retest reliability was not as high, possibly because of the high susceptibility of variation from 1 week to the next for frail elderly subjects. The 20- and 30.5-cm widths are recommended for future use of the PWT.
Iaith wreiddiol | Saesneg |
---|---|
Tudalennau (o-i) | 812 - 817 |
Nifer y tudalennau | 5 |
Cyfnodolyn | Archives of Physical Medicine and Rehabilitation |
Cyfrol | 92 |
Rhif cyhoeddi | 5 |
Dynodwyr Gwrthrych Digidol (DOIs) | |
Statws | Cyhoeddwyd - 1 Mai 2011 |